Prioritize consumption according to capacity, demand and electricity price.
Status
Information about the loads in the facility. Consumption, available capacity and status of the components controlled by Priority.
Prioritization
The component list shows the status of guarded loads, change the priority easily by moving them up or down in the list.
VIP
Set up the time you want the load to be given the highest priority. This can be to ensure that there is enough time in a day to heat the water heater or to guarantee that heating is prioritized a few hours in the morning.
Electricity price
Priority can be used to turn off or de-prioritize loads during the most expensive hours of the day.
Smart prioritization
If there is too little available capacity for the next load, Priority will continue in the queue. It also takes into account consumption per phase. phase and can therefore also help to balance consumption.
Hibernation mode
To avoid power being allocated to components that do not currently need it, these are automatically put into sleep mode and Priority prioritizes the next load in the queue. Such components can for example be:
- Heating controlled by thermostats
- water heaters
- snow melting plant
When the load needs power again, it is automatically taken out of sleep and resumes its place in the queue.
Notifier
If Priority receives an error message from a component in the system, a group can be notified. This could, for example, be operations managers or installers.